Availability: | |
---|---|
6230/C3VL2071
EASIER
Insulated Deep Groove Ball Bearings
USD$550
High Precision Insulated Bearing 6230/C3VL2071 is Deep Groove Ball Bearing design. its dimension is 150×270×45mm, it has the same dimension and the same design with normal chrome steel 6328 M/C3 bearing. but the most different is 6230-J20AA-C3 bearing with Aluminium Oxide Coating. the coating can Electrical Resistance Voltages up to 3000 V DC. This kind of bearing are widely used in high quality demand application like traction motor.
Electrically Insulated Bearing can protect the machine to be exposed to electrical current. In a worst-case scenario, this can damage raceways and rolling elements, which in turn, causes the motor or generator to fail prematurely and without warning. On top of the extra expenses incurred for repairs, this also means additional costs caused by machine downtime and the resulting production losses.
Principle bearing types for traction motor applications
• cylindrical roller bearings
• electrically insulated EASIER cylindrical roller bearings
• electrically insulated EASIER deep groove ball bearings
• hybrid cylindrical roller bearings with ceramic rollers
• hybrid deep groove ball bearings with ceramic balls
• traction motor bearing units based on cylindrical roller bearings and deep groove ball bearings
• Sensorised traction motor bearing unit
• Regreasable traction motor bearing unit
Electrically Insulated Cylindrical roller bearings and electrically deep groove ball bearings are the most used type, outer ring or inner ring coated is the best choice for insulated function, hybrid cylindrical roller bearing with ceramic rollers and hybrid ball bearings with ceramic balls are higher cost then the bearing rings coating.
Designation | Principal dimensions | Basic load ratings | Fatique load limit | Speed ratings | Weight | ||||
Deep groove ball bearing | mm | mm | mm | dynamic | static | Reference speed | Limiting speed | kg | |
d | D | B | C[kN] | C0[kN] | [r/min] | [r/min] | |||
6322/C3VL0241 | 110 | 240 | 50 | 216 | 180 | 5.7 | 6000 | 3800 | 9.7 |
6322 M/C3VL0241 | 110 | 240 | 50 | 216 | 180 | 5.7 | 6000 | 5300 | 11 |
6224/C3VL0241 | 120 | 215 | 40 | 153 | 118 | 3.9 | 6300 | 4000 | 5.3 |
6324/C3VL2071 | 120 | 260 | 55 | 216 | 186 | 5.7 | 5600 | 3400 | 12.7 |
6324 M/C3VL2071 | 120 | 260 | 55 | 216 | 186 | 5.7 | 5600 | 5000 | 15 |
6226/C3VL2071 | 130 | 230 | 40 | 163 | 132 | 4.15 | 5600 | 3600 | 5.8 |
6326/C3VL2071 | 130 | 280 | 58 | 242 | 216 | 6.3 | 5000 | 3200 | 15.5 |
6326 M/C3VL2071 | 130 | 280 | 58 | 242 | 216 | 6.3 | 5000 | 4500 | 16.5 |
6228/C3VL2071 | 140 | 250 | 42 | 174 | 150 | 4.55 | 5300 | 3400 | 7.5 |
6328/C3VL2071 | 140 | 300 | 62 | 265 | 245 | 7.1 | 4800 | 3000 | 18.7 |
6328 M/C3VL2071 | 140 | 300 | 62 | 265 | 245 | 7.1 | 4800 | 4300 | 21.8 |
6230/C3VL2071 | 150 | 270 | 45 | 186 | 166 | 4.9 | 5000 | 3200 | 10 |
6330/C3VL2071 | 150 | 320 | 65 | 286 | 285 | 7.8 | 4300 | 2800 | 23 |
6332 M/C3VL2071 | 160 | 340 | 68 | 291 | 285 | 7.65 | 4000 | 3800 | 31 |
6334 M/C3VL2071 | 170 | 360 | 72 | 332 | 340 | 8.8 | 3800 | 3400 | 35 |
6336 M/C3VL2071 | 180 | 380 | 75 | 371 | 405 | 10.4 | 3600 | 3200 | 41 |
DC resistance
At room temperature, the layer typically has a
DC resistance of 1–10 GOhm, depending on the bearing size. As the temperature increases, the DC resistance
decreases exponentially, typically by approx. 40–50 % per 10 K. But even at operating temperatures of 60 °C
or even 80 °C, the insulating layer still has a resistance of several MOhm. According to Ohm’s law (I = U/R),
this means that voltages of up to 1 000 V only produce currents that are significantly below 1 mA, which are not critical for bearings.
AC resistance
The insulated unit acts like a capacitor (C) which can accumulate charges. When exposed to an AC voltage, this causes an alternating current to flow through the
contact area between the rolling element and raceway.
In the case of a harmonic time dependence with
angular frequency w, the rms values for current and voltage are calculated using the formula
Insulated bearings feature an insulating layer of aluminium oxide applied by a sophisticated plasma spray process for outstanding quality, which provide the following beneits:
• Resistance to common media used in bearing applications
• Protection over a wide range of operating temperatures
• Minimum electrical resistance of 200 MOhm
• Tested to withstand voltages of 3 000 V DC (coatings that can handle higher voltages can be quoted on request)
E-mail: sales@xrbearing.com, brandbearings@gmail.com
Skype:brandbearings
Whatsapp: 0086-13280450757
www.xrbearing.com
High Precision Insulated Bearing 6230/C3VL2071 is Deep Groove Ball Bearing design. its dimension is 150×270×45mm, it has the same dimension and the same design with normal chrome steel 6328 M/C3 bearing. but the most different is 6230-J20AA-C3 bearing with Aluminium Oxide Coating. the coating can Electrical Resistance Voltages up to 3000 V DC. This kind of bearing are widely used in high quality demand application like traction motor.
Electrically Insulated Bearing can protect the machine to be exposed to electrical current. In a worst-case scenario, this can damage raceways and rolling elements, which in turn, causes the motor or generator to fail prematurely and without warning. On top of the extra expenses incurred for repairs, this also means additional costs caused by machine downtime and the resulting production losses.
Principle bearing types for traction motor applications
• cylindrical roller bearings
• electrically insulated EASIER cylindrical roller bearings
• electrically insulated EASIER deep groove ball bearings
• hybrid cylindrical roller bearings with ceramic rollers
• hybrid deep groove ball bearings with ceramic balls
• traction motor bearing units based on cylindrical roller bearings and deep groove ball bearings
• Sensorised traction motor bearing unit
• Regreasable traction motor bearing unit
Electrically Insulated Cylindrical roller bearings and electrically deep groove ball bearings are the most used type, outer ring or inner ring coated is the best choice for insulated function, hybrid cylindrical roller bearing with ceramic rollers and hybrid ball bearings with ceramic balls are higher cost then the bearing rings coating.
Designation | Principal dimensions | Basic load ratings | Fatique load limit | Speed ratings | Weight | ||||
Deep groove ball bearing | mm | mm | mm | dynamic | static | Reference speed | Limiting speed | kg | |
d | D | B | C[kN] | C0[kN] | [r/min] | [r/min] | |||
6322/C3VL0241 | 110 | 240 | 50 | 216 | 180 | 5.7 | 6000 | 3800 | 9.7 |
6322 M/C3VL0241 | 110 | 240 | 50 | 216 | 180 | 5.7 | 6000 | 5300 | 11 |
6224/C3VL0241 | 120 | 215 | 40 | 153 | 118 | 3.9 | 6300 | 4000 | 5.3 |
6324/C3VL2071 | 120 | 260 | 55 | 216 | 186 | 5.7 | 5600 | 3400 | 12.7 |
6324 M/C3VL2071 | 120 | 260 | 55 | 216 | 186 | 5.7 | 5600 | 5000 | 15 |
6226/C3VL2071 | 130 | 230 | 40 | 163 | 132 | 4.15 | 5600 | 3600 | 5.8 |
6326/C3VL2071 | 130 | 280 | 58 | 242 | 216 | 6.3 | 5000 | 3200 | 15.5 |
6326 M/C3VL2071 | 130 | 280 | 58 | 242 | 216 | 6.3 | 5000 | 4500 | 16.5 |
6228/C3VL2071 | 140 | 250 | 42 | 174 | 150 | 4.55 | 5300 | 3400 | 7.5 |
6328/C3VL2071 | 140 | 300 | 62 | 265 | 245 | 7.1 | 4800 | 3000 | 18.7 |
6328 M/C3VL2071 | 140 | 300 | 62 | 265 | 245 | 7.1 | 4800 | 4300 | 21.8 |
6230/C3VL2071 | 150 | 270 | 45 | 186 | 166 | 4.9 | 5000 | 3200 | 10 |
6330/C3VL2071 | 150 | 320 | 65 | 286 | 285 | 7.8 | 4300 | 2800 | 23 |
6332 M/C3VL2071 | 160 | 340 | 68 | 291 | 285 | 7.65 | 4000 | 3800 | 31 |
6334 M/C3VL2071 | 170 | 360 | 72 | 332 | 340 | 8.8 | 3800 | 3400 | 35 |
6336 M/C3VL2071 | 180 | 380 | 75 | 371 | 405 | 10.4 | 3600 | 3200 | 41 |
DC resistance
At room temperature, the layer typically has a
DC resistance of 1–10 GOhm, depending on the bearing size. As the temperature increases, the DC resistance
decreases exponentially, typically by approx. 40–50 % per 10 K. But even at operating temperatures of 60 °C
or even 80 °C, the insulating layer still has a resistance of several MOhm. According to Ohm’s law (I = U/R),
this means that voltages of up to 1 000 V only produce currents that are significantly below 1 mA, which are not critical for bearings.
AC resistance
The insulated unit acts like a capacitor (C) which can accumulate charges. When exposed to an AC voltage, this causes an alternating current to flow through the
contact area between the rolling element and raceway.
In the case of a harmonic time dependence with
angular frequency w, the rms values for current and voltage are calculated using the formula
Insulated bearings feature an insulating layer of aluminium oxide applied by a sophisticated plasma spray process for outstanding quality, which provide the following beneits:
• Resistance to common media used in bearing applications
• Protection over a wide range of operating temperatures
• Minimum electrical resistance of 200 MOhm
• Tested to withstand voltages of 3 000 V DC (coatings that can handle higher voltages can be quoted on request)
E-mail: sales@xrbearing.com, brandbearings@gmail.com